APC Smart-UPS RT 20kVA RM 230V | SURT20KRMXLI
SURT20KRMXLI
APC Smart-UPS RT 20kVA RM 230V
·         Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
·         LCD display
Alpha-Numeric Display which displays system parameters and alarms.
·         Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
·         Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
·         Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.
·         Single or three-phase input wireable
Provides flexibility for the UPS to be installed using either single or three-phase input wiring.
Smart-UPS On-LineFeatures & Benefits
Availability
·         Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
·         Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
·         Scalable runtime
Allows additional run time to be quickly added as needed.
·         Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
·         Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
·         Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Manageability
·         Serial connectivity
Provides management of the UPS via a serial port.
·         LED status indicators
Quickly understand unit and power status with visual indicators.
·         Network manageable
Provides remote power management of the UPS over the network.
·         SmartSlot
Customize UPS capabilities with management cards.
·         InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Adaptability
·         Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
·         Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
·         Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Serviceability
·         User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
·         Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
·         Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
·         Disconnected battery notification
Warns when a battery is not available to provide backup power.
·         Audible alarms
Provides notification of changing utility power and UPS power conditions
Protection
·         Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
·         Cold-start capable
Provides temporary battery power when the utility power is out.
·         Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
·         Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
·         Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
·         Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
·         Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Output
·         Output power capacity
16.0 KWatts / 20.0 kVA
·         Max Configurable Power (Watts)
16.0 KWatts / 20.0 kVA
·         Nominal Output Voltage
230V
·         Output Voltage Note
Configurable for 400 or 415V 3 Phase nominal output voltage
·         Output Voltage Distortion
Less than 5%
·         Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1
·         Other Output Voltages
220, 240
·         Load Crest Factor
3 : 1
·         Topology
Double Conversion Online
·         Waveform type
Sine wave
·         Overload Operation
60 seconds @ 125% and 30 seconds @ 150%
·         Output Connections
(2) IEC Jumpers (Battery Backup)
(8) IEC 320 C19 (Battery Backup)
(1) Hard Wire 3-wire (H N + G) (Battery Backup)
·         Bypass
Built-in Static Bypass, Internal Bypass (Automatic and Manual), Optional External Bypass
Input
·         Nominal Input Voltage
230V , 400V 3PH
·         Input frequency
40 - 70 Hz (auto sensing)
·         Input Connections
Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
·         Input voltage range for main operations
160 - 280V
·         Input Total Harmonic Distortion
Less than 5% for full load
·         Other Input Voltages
220, 240
·         Maximum Input Current
115.0A
·         Input Power Factor at Full Load
0.98
Batteries & Runtime
·         Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
·         Included Battery Modules
4
·         Typical recharge time
2.5hour(s)
·         Nominal Battery Voltage
+/-192 V (split battery referenced to neutral)
·         Replacement Battery
APCRBC140
·         Expected Battery Life (years)
3 - 5
·         RBC Quantity
4
·         Extendable Run Time
1
·         Extended Run Options
APC-Smart-UPS-RT-20kVA-RM-230V
·         End of Discharge Battery Voltage
+/-154 V
·         Efficiency in Battery Operation
93.0 %
·         Runtime
View Runtime Graph
View Runtime Chart
·         Efficiency
View Efficiency Graph
Communications & Management
·         Interface Port(s)
DB-9 RS-232 , RJ-45 10/100 Base-T , Smart-Slot
·         Pre-Installed SmartSlot™ Cards
AP9631
·         Control panel
Multi-function LCD status and control console
·         Audible Alarm
Audible and visible alarms : configurable delays
·         Emergency Power Off (EPO)
Yes
Surge Protection and Filtering
·         Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
·         Maximum Height
533mm , 53.3CM
·         Maximum Width
432mm , 43.2CM
·         Maximum Depth
773mm , 77.3CM
·         Rack Height
12U
·         Net Weight
247.73KG
·         Shipping weight
314.09KG
·         Shipping Height
990mm , 99.0CM
·         Shipping Width
610mm , 61.0CM
·         Shipping Depth
1003mm , 100.3CM
·         Color
Black
·         Units per Pallet
1.0
Environmental
·         Operating Temperature
0 - 40 °C
·         Operating Relative Humidity
0 - 95% non-condensing %
·         Operating Elevation
0-3000meters
·         Storage Temperature
-15 - 45 °C
·         Storage Relative Humidity
0 - 95% non-condensing %
·         Storage Elevation
0-15000meters
·         Audible noise at 1 meter from surface of unit
59.0dBA
·         Online thermal dissipation
3770.0BTU/hr
·         Protection Class
IP 20
Conformance
·         Approvals
BSMI, EN/IEC 62040-2, EN/IEC 62040-1-1, VDE
·         Standard warranty
2 years repair or replace
Sustainable Offer Status
·         RoHS
Compliant
·         REACH
REACH: Contains No SVHCs
·         PEP
Available in Documentation tab
·         EOLI
Available in Documentation tab
·         Battery Directive
Compliant
·         Battery Notes
ts_Battery_Notes