Array ( [#commerce_product] => stdClass Object ( [__CLASS__] => Drupal\commerce_product\Entity\Product [defaultVariation:protected] => [values:protected] => Array ( [product_id] => Array ( [x-default] => 7545 ) [type] => Array ( [x-default] => computing_accessories ) [uuid] => Array ( [x-default] => 1ac79426-f43f-4e0f-afe1-401c38f6b4cc ) [langcode] => Array ( [x-default] => en ) [uid] => Array ( [x-default] => 17 ) [status] => Array ( [x-default] => 1 ) [title] => Array ( [x-default] => Mercury 3KVA Online UPS|Single Phase|96VDC|Internal Battery ) [created] => Array ( [x-default] => 1415107260 ) [changed] => Array ( [x-default] => 1590672255 ) [default_langcode] => Array ( [x-default] => 1 ) [stores] => Array ( [x-default] => Array ( [0] => Array ( [target_id] => 1 ) ) ) [variations] => Array ( [x-default] => Array ( [0] => Array ( [target_id] => 3657 ) ) ) [body] => Array ( [x-default] => Array ( [0] => Array ( [value] =>The Mercury 3kva Online UPS will provide your power backup requirement for sensitive, mission-critical applications that must have always-on power supply with zero switching time. If your equipment will not tolerate any break in power supply, you need this high frequency, double conversion online technology Mercury Uninterruptible Power Supply. The 3kva Mercury online UPS, with output rating of 2100W, will provide stable, clean, zero transfer rate power backup to support equipment like network systems, servers, workstations and other IT equipment. With sensitive applications, you need more than a regular standby UPS or even a line-interactive UPS. The online UPS is the clear choice for maximum power protection for such applications.
Key Features
- Application: For networks, servers and other IT equipment or similar mission-critical equipment
- High frequency and double conversion on-line technology
- Fully digitised microprocessor control
- Wide input voltage range
- LCD display
- UPS startup without battery
- Cold start
- Advanced battery management
- Automatic battery charge in UPS off mode
- Lightning and surge protection
- Short circuit and overload protection
- speed auto control when loads varies
- Network/Fax/Modem surge protection
- Optional extension battery pack
- Battery voltage display
- Load capacity display
- EMI/RFI noise filter
- Smart RS232 communication with monitoring software
- Optional SNMP Card slot
- EPO function(optional)
- Input L and N reversed alarm function
Capacity | 3KVA / 2100W |
Phase | Single Phase |
Input voltage | 115VAC(±5) ~ 295VAC(±5) if load ? 70%; 160VAC(±5) ~ 295VAC(±5) if load ? 70% |
Frequency | 46 ~ 54(50Hz)±0.5Hz; 56 ~ 64(60Hz)±0.5Hz auto sensing |
Input power factor | ? 0.97 |
Output voltage | 220/230VAC ± 2% |
Frequency | 50Hz / 60Hz ± 0.2% |
THD | < 3% (linear load); < 6% (non linear load) |
Overload capability | > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode |
Crest factor | 3:1 (max) |
Short circuit protection | 5 cycles turn off inverter, no transfer tp bypass, provide alarm (AC mode); 5 cycles turn off inverter, provide alarm (AC mode); Unput fuse blown or breaker action (bypass mode) |
Waveform | Pure sine wave |
Transfer time | 0ms between AC mode & Bypass mode 4ms (typical 2.5ms) between Inverter mode & Bypass mode |
Efficiency | ? 85% |
Model | 12V sealed lead acid maintenance free |
Battery | 8x 12V / 7AH |
DC voltage | 96VDC |
Back-up | 16min (half load); 5min (full load) |
Recharge time | 8hours ~ 90% capacity |
Charge current | 1A(standard unit);6A(long time unit) |
Communication interface | RS232 ; SNMP (optional) |
LED indication | Load or battery capacity |
Noise level | < 45dB |
Temperature | 0 ~ 40?C |
Humidity | 0% ~ 95% (non-condensing) |
Altitude | < 1500m |
Storage temperature | -25 ~ 55?C |
Standard unit (net/gross) | 34 / 36kg |
Long time unit (net/gross) | 15 / 17kg |
Dimension (WxDxH)mm | 191 x 478 x 339mm |
Packing(WxDxH)mm | 332 x 603 x482 |