Call To Order
Variable
Array ( [#commerce_product] => stdClass Object ( [__CLASS__] => Drupal\commerce_product\Entity\Product [defaultVariation:protected] => [values:protected] => Array ( [product_id] => Array ( [x-default] => 21197 ) [type] => Array ( [x-default] => electrical_power_devices ) [uuid] => Array ( [x-default] => 2ca0d37f-163d-43ee-a3e1-dedabaea5183 ) [langcode] => Array ( [x-default] => en ) [uid] => Array ( [x-default] => 1 ) [status] => Array ( [x-default] => 1 ) [title] => Array ( [x-default] => APC Power-Saving Back-UPS Pro 1500, 230V | BR1500GI ) [created] => Array ( [x-default] => 1538663066 ) [changed] => Array ( [x-default] => 1600167400 ) [default_langcode] => Array ( [x-default] => 1 ) [stores] => Array ( [x-default] => Array ( [0] => Array ( [target_id] => 1 ) ) ) [variations] => Array ( [x-default] => Array ( [0] => Array ( [target_id] => 15704 ) ) ) [body] => Array ( [x-default] => Array ( [0] => Array ( [value] =>BR1500GI Features
APC Power-Saving Back-UPS Pro 1500, 230V
-
Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
-
Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
Boost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
-
Building Wiring Fault IndicatorThis LED informs users of potentially dangerous wiring problems in the wall circuit.
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
Extendable Run TimeAdditional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.
-
Power-saving outletsAutomatically cuts power to idle equipment to conserve electricity.
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Serial connectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
-
Telephone dataline surge protectionProvides protection of connected equipment from power surges traveling on telephone lines.
-
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
-
USB connectivityProvides management of the UPS via a USB port (not available on all models).
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Marketing Features
-
Boost Automatic Voltage Regulation (AVR)Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Availability
-
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Customizable voltage sensitivityToggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Customizable voltage-transfer pointsAdjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Protection
-
Surge only outletsProtect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
-
Battery and surge protected outletsBack up and protect your hardware and data during power outages, surges and spikes.
Manageability
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
-
USB connectionUse your PC to access additional power protection and management features for your UPS via a USB Port.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
Serviceability
-
Simple battery replacementIncreases UPS availability by allowing quick, easy battery replacement.
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.